DESCRIPTION
The SerialComm TTL-232-5P is a very high quality and reliable compact bi-directional port-powered RS232 to 5V TTL converter which converts full-duplex RS232 to 5V TTL, This converter is ideal for any demanding application whether indoor in a lab, server room, office, at home or outdoors within the temperature range of -4ºF to 140ºF (-20ºC to 60ºC). The converter is port-powered and derives power by amplifying the RS232 data lines requiring no external power at all. This converter features auto sensing data turnaround eliminating the need for software drivers or handshake flow control. The TTL-232-5P has a DB9 female connector on the RS232 end, and DB9 male connector on the TTL end. A separate terminal block with no exposed jumpers is included with purchase. The terminal block plugs into the TTL end of the converter, providing screw-lug wire terminations for the port.
SERIAL RS232 TO 5V TTL CONVERTER
90-day Money Back Guarantee / 5-year Replacement Warranty
![RS232 to TTL Converter](images/products/rs232_rs485_to_ttl/ttl-232-5p/CONV_TTL-232-5P_big.jpg)
SerialComm Model: TTL-232-5P
FEATURES
- Plug-and-Play (hot-pluggable)
- Includes terminal block with no exposed jumpers
- Flexible DB9 cable or screw down wire installation
- Operates from 300 to 115.2K baud
- Port powered - no external power needed
- Data direction auto-turnaround - no software is necessary
- Built-in 600W surge protection
- Built-in 15KV static protection
- MTBF(Mean Time Before Failure): 249,914 Hours
- 5-year manufacturer's warranty
- CE, FCC, RoHS 3, and REACH certified
- Manufactured to ISO-9001:2015 standards
COMMUNICATION | |
STANDARDS: | EIA/TIA RS232 Standard |
BAUD RATES: | From 300 Baud To 115,200 Baud |
CONNECTOR TYPES: | RS232 Side: DB9 Female and TTL Side: either DB9 Male or 5 Way Terminal Block |
DISTANCE: | RS232 Side: 16 ft (5m) and TTL Side: up to 10 ft (3m) |
ELECTRICAL | |
POWER SOURCE: | Port Powered From RS232 Data Lines |
CURRENT CONSUMPTION: | Less Than 10 mA |
STATIC PROTECTION: | 15KV Electric Static Discharge (ESD) Protection |
SURGE PROTECTION: | 600W Surge Protection |
MECHANICAL | |
HOUSING: | Rugged ABS |
WEIGHT: |
With Terminal Block: 1.2oz (36 grams) Without Terminal Block: 0.8oz (24 grams) |
DIMENSIONS: |
With Terminal Block: 3.16 X 1.32 X 0.73
in (80.3 X 33.4 X 18.6 mm) Without Terminal Block: 2.47 X 1.33 X 0.70 in (62.8 X 33.8 X 17.8 mm) |
ENVIRONMENTAL | |
OPERATING TEMP.: | -4ºF to 140ºF (-20ºC to 60ºC) |
STORAGE TEMP.: | -40ºF to 185ºF (-40ºC to 85ºC) |
OPERATING HUMIDITY: | 5% To 95% - No Condensation |
QUALITY | |
PRODUCT SAFETY: | CE, FCC, RoHS 3, and REACH certified |
QUALITY MANAGEMENT: | Manufactured and Distributed to ISO 9001:2015 QMS |
MEAN TIME BEFORE FAILURE: | 249,914 Hours |
RELIABILITY: | Low Failure Rate - 99+% Reliability Since Inception |
WARRANTY: | 5-year Replacement Warranty |
TTL VOLTAGE LEVELS
TTL INPUT |
TTL OUTPUT |
HIGH ( > 2.0V ) |
HIGH (5.0V) |
LOW ( < 0.8V ) |
LOW (0.0V) |
RS232 SIDE
SIGNAL | DCD | DTR | DSR | RTS | CTS | TX | RX | GND |
PIN # | 1 | 4 | 6 | 7 | 8 | 2 | 3 | 5 |
FUNCTION | TIED | TIED | TX | RX | GND |
DB9 FEMALE
![](application_drawings/application_DB9female.jpg)
5V TTL SIDE
SIGNAL | NC | TTL IN |
TTL OUT |
NC | GND |
PIN # | 1 | 2 | 3 | 4 | 5 |
FUNCTION | NC | TTL IN |
TTL OUT |
NC | GND |
DB9 MALE OR TERMINAL BLOCK
![](application_drawings/applicaiton_DB9male.jpg)
![RS232 to TTL Converter](application_drawings/application_TBLOCK-TTL-232.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_one_lg.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_4_lg.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_3_lg.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_2_lg.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_lg.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_1_lg.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_5_lg.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_one_thumb.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_4_thumb.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_3_thumb.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_2_thumb.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_thumb.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_1_thumb.jpg)
![](images/products/rs232_rs485_to_ttl/ttl-232-5p/gallery/TTL_232_5P_5_thumb.jpg)
Using one TTL-232-5P unit:
Check that all connections comply with the connection diagrams. Perform a loop back test on one unit: Connect the IN to OUT on the TTL port. Connect the RS232 port to the PC RS232 port. Running a hyper terminal program on the PC, send ASCII characters to the TTL-232-5P converter from one PC port, and check that the characters are received at the same PC port. This tests that the transmit and receive functions of the TTL-232-5P unit is working properly.
Using two TTL-232-5P unit:
Check that all connections comply with the connection diagrams. Perform a loop back test on two units: Connect the two TTL ports. Connect the two RS232 ports to two PC RS232 ports. Running hyper terminal programs on both PCs, send ASCII characters to the TTL-232-5P converter from one PC port, and check that the characters are received at the 2nd PC port. Repeat the test in the opposite direction. This tests that the transmit and receive functions of both TTL-232-5P units are working properly.
Download FREE FULL VERSION AccessPort Advanced Serial Monitor, Simulation and Data Analysis Software Tool. This software tool is great for testing converters. Supports Windows 98/XP/VISTA/WIN 7/8/10/11. DOWNLOAD SOFTWARE AND USER MANUAL