DESCRIPTION

The SerialComm TTL-232-33IE is a very high quality and reliable compact industrial-grade bi-directional port-powered RS232 to 3.3V TTL converter which converts full-duplex RS232 to a low voltage 3.3V TTL, This converter is ideal for any demanding application whether indoor in a lab, server room, office, at home or outdoors within the temperature range of -40ºF to 185ºF (-40ºC to 85ºC). The converter is port-powered and derives power by amplifying the RS232 data lines requiring no external power at all but also have the option to add external 5V power. This converter features auto sensing data turnaround eliminating the need for software drivers or handshake flow control. The TTL-232-33IE has a DB9 female connector on the RS232 end, and DB9 male connector on the TTL end. A separate terminal block with no exposed jumpers is included with purchase. The terminal block plugs into the TTL end of the converter, providing screw-lug wire terminations for the port.

PORT-POWERED WITH OPTIONAL EXTERNAL POWER

The SerialComm TTL-232-33IE has an optional 5V DC external power input, The TTL-232-33IE is normally port-powered from the RS232 data lines while using a capacitor charge pump built into the converter to provide necessary power. There are rare instances where the RS232 host device is not capable of port-powering the converter due to signal incompatibilities or low voltage levels. If this should occur, all that is necessary is adding a 5V DC external power to the terminal block or DB9 connector. Because the TTL-232-33IE is industrial grade and port-powered with an optional 5V power input it makes this converter one of the most versatile RS232 to TTL converters on the market.

INDUSTRIAL RS232 TO 3.3V TTL CONVERTER WITH OPTIONAL EXT. POWER

30-day Money Back Guarantee / 5-year Replacement Warranty
Industrial RS232 to 3.3V TTL Converter

SerialComm Model: TTL-232-33IE

Price: $18.95

FEATURES

  • Plug-and-Play (hot-pluggable)
  • Includes terminal block with no exposed jumpers
  • Flexible DB9 cable or screw down wire installation
  • Operates from 300 to 115.2K baud
  • Port powered - no external power needed
  • Data direction auto-turnaround - no software is necessary
  • Built-in 600W surge protection
  • Built-in 15KV static protection
  • MTBF(Mean Time Before Failure): 306,000 Hours
  • 5-year manufacturer's warranty
  • CE, FCC, RoHS 3, and REACH certified
  • Manufactured to ISO-9001:2015 standards

DATASHEETS


2D CAD DRAWINGS AND 3D MODELS

COMMUNICATION
STANDARDS: EIA/TIA RS232 Standard
BAUD RATES: From 300 Baud To 115,200 Baud
CONNECTOR TYPES: RS232 Side: DB9 Female and TTL Side: either DB9 Male or 4-way Terminal Block
DISTANCE: RS232 Side: 16 ft (5m) and TTL Side: up to 10 ft (3m)
ELECTRICAL
POWER SOURCE: Port Powered From RS232 Data Lines - Optional 5V External Power
CURRENT CONSUMPTION: Less Than 10 mA
STATIC PROTECTION: 15KV Electric Static Discharge (ESD) Protection
SURGE PROTECTION: 600W Surge Protection
MECHANICAL
HOUSING: Rugged ABS
WEIGHT: With Terminal Block: 1.2oz (36 grams)
Without Terminal Block: 0.8oz (24 grams)
DIMENSIONS: With Terminal Block: 3.53 X 1.33 X 0.70 in (89.6 X 33.8 X 17.8 mm)
Without Terminal Block: 2.47 X 1.33 X 0.70 in (62.8 X 33.8 X 17.8 mm)
ENVIRONMENTAL
OPERATING TEMP.: -40ºF to 185ºF (-40ºC to 85ºC)
STORAGE TEMP.: -40ºF to 185ºF (-40ºC to 85ºC)
OPERATING HUMIDITY: 5% To 95% - No Condensation
QUALITY
PRODUCT SAFETY: CE, FCC, RoHS 3, and REACH certified
QUALITY MANAGEMENT: Manufactured and Distributed to ISO 9001:2015 QMS
MEAN TIME BEFORE FAILURE: 306,000 Hours
RELIABILITY: Low Failure Rate - 99+% Reliability Since Inception
WARRANTY: 5-year Replacement Warranty

TTL VOLTAGE LEVELS

TTL INPUT

TTL OUTPUT

HIGH ( > 2.0V )

HIGH (3.3V)

LOW ( < 0.8V )

LOW (0.0V)

RS232 SIDE

SIGNAL TX RX GND
PIN # 2 3 5
FUNCTION TX RX GND

DB9 FEMALE

5V TTL SIDE

SIGNAL IN OUT GND VCC
PIN # 1 2 5 6
FUNCTION TTL
IN
TTL
OUT
GND 5V
OPT.

DB9 MALE OR TERMINAL BLOCK

Industrial RS232 to 3.3V TTL Converter

Using one TTL-232-33IE unit:

Check that all connections comply with the connection diagrams. Perform a loop back test on one unit: Connect the IN to OUT on the TTL port. Connect the RS232 port to the PC RS232 port. Running a hyper terminal program on the PC, send ASCII characters to the TTL-232-33IE converter from one PC port, and check that the characters are received at the same PC port. This tests that the transmit and receive functions of the TTL-232-33IE unit is working properly.

Using two TTL-232-33IE unit:

Check that all connections comply with the connection diagrams. Perform a loop back test on two units: Connect the two TTL ports. Connect IN to OUT and OUT to IN. Connect the two RS232 ports to two PC RS232 ports. Running hyper terminal programs on both PCs, send ASCII characters to the TTL-232-33IE converter from one PC port, and check that the characters are received at the 2nd PC port. Repeat the test in the opposite direction. This tests that the transmit and receive functions of both TTL-232-33IE units are working properly.

Download FREE FULL VERSION AccessPort Advanced Serial Monitor, Simulation and Data Analysis Software Tool. This software tool is great for testing converters. Supports Windows 98/XP/VISTA/WIN 7/8/10/11. DOWNLOAD SOFTWARE AND USER MANUAL

FIGURE 1: CONNECTING RS232 TO A 3.3V TTL DEVICE - PORT-POWER MODE

FIGURE 2: CONNECTING RS232 TO A 3.3V TTL DEVICE - 5V POWER MODE

2023 Copyright Protected - Sima S. Enterprises LLC - Terms & Conditions - Privacy Statement